FROZEN BEFORE EXECUTION · RECOMPUTABLE VERDICTS · EFFIQ · EFFIQ EST. 2026 EFFIQAUDITABLE INFERENCE OPTIMIZATION
LEDGER / 02 / ESSAY 002
02ESSAY 002OCTOBER 6, 2026

We replayed real production traffic at FP8: the 2.33× held — “no measurable quality loss” didn’t

PRODUCTION TRAFFIC REPLAYED · SEED-LOCKED · FULL LOGS PUBLIC

The last essay ended with a written promise: outside Pilot 001’s small world — one L40S, one hash-pinned model, one declared synthetic workload — we guarantee nothing. The question readers asked most: what about real traffic?

This time we did the laborious thing. We took Microsoft’s public Azure LLM inference trace (two production services, real arrival timestamps), cut a week of windows out of it, froze the subsampling rule in a signed amendment, and replayed the identical arrival process at two arms on a single L40S: BF16 and FP8. Odd and even runs alternate which arm goes first; requests are paired one by one; the decision rules were frozen before a single measurement existed.

The results first — one good, one bad, both verbatim from the sealed verdicts:

The 2.33× doesn’t live in the average — it lives at the knee

On the quieter hours the per-run speedups are unspectacular: paired log-ratios around +0.45 to +0.72, i.e. one-and-a-half to two×. The story is the heaviest hour: the real evening peak arrives, and BF16’s queue collapses on contact — pooled P95 time-to-first-token 37.272 s, versus 1.861 s on FP8; that run’s log-ratio is +2.238, nearly nine×.

This is what synthetic workloads never measure: the value of quantization is not “faster on average” — it’s that the capacity knee sits at a different place. The same flood hits both arms; one arm’s tail latency sails to seven× the SLO reference line while the other doesn’t flinch. If you plan capacity to BF16’s knee, a peak means buying more GPUs. Plan to FP8’s knee, and you buy nothing. For a compute bill, the knee’s location is worth more than the average speed.

Honest disclosure: the trace peaks at roughly 50× what a single L40S can serve, so the replay is thinned and compressed under a frozen rule (Amendment-01, signed with zero measurement data in existence); both arms face byte-identical arrivals. We measured relative ratios and the shape of the knee — not absolute production QPS.

How the FAIL was handled

The rule was frozen: the overall delta and every per-axis delta must all be ≥ −0.1. Clarity came in at −0.127, over the line by 0.027.

Notice what’s not on our menu: “have the judge re-score it,” “move the bar to 0.15,” “try a different set of items.” The point of freezing the rule is that it doesn’t negotiate when it fires — including at us. The FAIL went into the record, the verdict document is public, and it was published no later than a PASS would have been.

Then we went and doubted our own judge

Filing the FAIL didn’t end the questions. We chased it on two levels. First, post-hoc analysis (explicitly labeled: descriptive, verdict unchanged): the same judge model, scoring the same arm-A answer sheets two days apart, drifted by 0.67–0.91 points; and the per-item score damage across our two pilots correlates at −0.002 — if FP8 truly hurt particular items, the wounds should overlap. They don’t overlap at all.

Second, a formal follow-up: a separate pre-registration (frozen before execution) handed the sealed 150 answer pairs, presentation order untouched, to an independent judge panel. Result: every axis delta from both panel judges came out positive — clarity at +0.127 and +0.193 — same day, same model family, same answer sheets, sign-flipped against the original judge’s −0.127. Panel outcome: the original FAIL is judge-fragile, consistent with single-judge noise.

One number that made us blink: the two new judges graded both arms about 1.5 points lower overall. Judges don’t even share a scale — which is why our protocol only ever trusts within-match differentials, never absolute scores.

The lesson now enters our engineering standard: a single-judge ±0.1 tolerance sits below the judge’s own noise floor. From the next pilot onward, the quality gate is a multi-judge panel by default.

So what holds, exactly

This is what we sell — not a number, an envelope map: where it’s green, where it’s red, and the configuration that keeps you in the green, every line of it anchored to raw logs you can recompute.

Don’t trust us. Recompute us.

The whole evidence chain is public: the frozen protocol and its amendments, the raw logs of every run, the judge’s verbatim per-item responses, the follow-up’s pre-registration and amendment, three verdict documents. Three --verify commands — no network, no GPU — recompute every number from the raw logs by hand: the FAIL, and the ROBUST-CLEAR that overturned its judge.

Optimization is the product; measurement is the moat. An envelope map is worth more than a poster.


Evidence chain: protocol & scripts — github.com/effiq/pilot002 | raw evidence — sha256 custody, available on request for audit | verdict: VERDICT.md (incl. the addendum outcome) | reproduction: REPRODUCE.md | previous essay: Your quantization speedup doesn’t transfer to your workload

中文版本:《把真实流量回放给 FP8:2.33× 活下来了,“质量无损”这次没能证明》